T1 - Investigation of indoor environment quality of Chinese large-hub airport terminal buildings through longitudinal field measurement and subjective survey
AU - Wang, Zhe
AU - Zhao, Haitian
AU - Lin, Borong
AU - Zhu, Yingxin
AU - Ouyang, Qin
AU - Yu, Juan
N1 - Publisher Copyright:
© 2015 Elsevier Ltd.
PY - 2015/12/1
Y1 - 2015/12/1
N2 - With the economic growth, a large number of airports are being or planned to be constructed or retrofitted in China. Airport terminal buildings have its unique Indoor Environment Quality (IEQ) performance due to its special architectural and operational features. In this research, instrumental objective measurements and questionnaire subjective surveys have been performed to investigate the IEQ of eight major Chinese large-hub airport terminal buildings. The questionnaire surveys show that the majority of overall satisfactory level of the airport terminal buildings lies between just satisfied and satisfied. The environmental factors can explain a part of but not all the variation of travelers' overall satisfactory level. Thermal environment and air quality are the two crucial factors for the overall satisfactory level. Instrumental measurements find that the black globe temperature in departure lounge is averagely 3-5 °C higher than air temperature due to large external glazing. By comparing the subjective and objective observations, the variation of thermal satisfactory level is found to be not as significant as the variation of thermal qualification rate, and travelers' air quality satisfactory level is highly correlated with the CO2 concentration of airport terminals.
AB - With the economic growth, a large number of airports are being or planned to be constructed or retrofitted in China. Airport terminal buildings have its unique Indoor Environment Quality (IEQ) performance due to its special architectural and operational features. In this research, instrumental objective measurements and questionnaire subjective surveys have been performed to investigate the IEQ of eight major Chinese large-hub airport terminal buildings. The questionnaire surveys show that the majority of overall satisfactory level of the airport terminal buildings lies between just satisfied and satisfied. The environmental factors can explain a part of but not all the variation of travelers' overall satisfactory level. Thermal environment and air quality are the two crucial factors for the overall satisfactory level. Instrumental measurements find that the black globe temperature in departure lounge is averagely 3-5 °C higher than air temperature due to large external glazing. By comparing the subjective and objective observations, the variation of thermal satisfactory level is found to be not as significant as the variation of thermal qualification rate, and travelers' air quality satisfactory level is highly correlated with the CO2 concentration of airport terminals.
KW - Airport terminals
KW - Indoor environment Quality (IEQ)
KW - Post-Occupancy Evaluation (POE)
UR - https://www.webofscience.com/wos/woscc/full-record/WOS:000367759400012
UR - https://openalex.org/W1855073810
UR - https://www.scopus.com/pages/publications/84946711254
U2 - 10.1016/j.buildenv.2015.10.014
DO - 10.1016/j.buildenv.2015.10.014
M3 - Journal Article
SN - 0360-1323
VL - 94
SP - 593
EP - 605
JO - Building and Environment
JF - Building and Environment
ER -