TY - GEN
T1 - Research on layout of measurement points in tunnel lighting experiment
AU - Yang, Qiang
AU - Liang, Bo
AU - Pan, Guo Bing
AU - He, Shi Yong
AU - Chen, Wei
AU - Dang, Xiao Yu
AU - Wu, Zhi Wei
PY - 2014
Y1 - 2014
N2 - Based on the measured data of the tunnel lighting, this paper is focusing on the arrangement of measured points in the experiment of tunnel lighting. Through the way of changing the location of measured area and the arrangement of measured points, comparing the simulation from the software DIALUX and the actual measurement in a repetitive region, the best position of measured area and the corresponding layout mode can be found. Analysis shows that, the larger the lamp distance is, the more similar the experiment and simulation results are. Before the experiment, the analysis of the light distribution curve is required, then, the simulation of software can help to find out the best position of lamp interval, measured area and layout mode, in order to ensure the authenticity of the results and to avoid too large or too small lighting evaluation, layout mode must include the maximum measured points and the minimum measured point.
AB - Based on the measured data of the tunnel lighting, this paper is focusing on the arrangement of measured points in the experiment of tunnel lighting. Through the way of changing the location of measured area and the arrangement of measured points, comparing the simulation from the software DIALUX and the actual measurement in a repetitive region, the best position of measured area and the corresponding layout mode can be found. Analysis shows that, the larger the lamp distance is, the more similar the experiment and simulation results are. Before the experiment, the analysis of the light distribution curve is required, then, the simulation of software can help to find out the best position of lamp interval, measured area and layout mode, in order to ensure the authenticity of the results and to avoid too large or too small lighting evaluation, layout mode must include the maximum measured points and the minimum measured point.
KW - DIALux
KW - Layout mode
KW - Measurement area
KW - Range of light effects
KW - Tunnel lighting experiment
UR - https://www.scopus.com/pages/publications/84904975772
U2 - 10.4028/www.scientific.net/AMM.580-583.1024
DO - 10.4028/www.scientific.net/AMM.580-583.1024
M3 - Conference Paper published in a book
AN - SCOPUS:84904975772
SN - 9783038351658
T3 - Applied Mechanics and Materials
SP - 1024
EP - 1028
BT - Advances in Civil and Industrial Engineering IV
PB - Trans Tech Publications Ltd
T2 - 4th International Conference on Civil Engineering, Architecture and Building Materials, CEABM 2014
Y2 - 24 May 2014 through 25 May 2014
ER -