Investigations of active, passive and hybrid thermal management systems for lithium-ion batteries

  • Qianli YUE

Student thesis: Doctoral thesis

Abstract

Lithium-ion batteries have been widely used in various applications such as portable devices, electric vehicles and power stations, as they offer distinctive merits of high energy density, high power density, high efficiency and long lifespan. During battery operation, a large amount of heat will be inevitably generated, resulting in elevated temperatures, which will intensify side reaction, accelerate battery aging and even cause safety problem. The primary objective of this thesis is to address these thermal issues by developing efficient thermal management systems for lithium-ion batteries, thereby ensuring their safe and high-performing operation.

We start with designing and modeling an active thermal management system that uses liquid cooling plates inserted between cells to dissipate heat generated from the batteries. The effects of geometric and operational parameters on the thermal performance and power consumption of serpentine-channel and parallel-channel liquid cooling plates are systematically investigated based on three-dimensional modeling. Numerical results show that, for both types of cooling plates, increasing flow channel width could reduce the maximum temperature of the battery, while changing channel depth has little influence on thermal performance. Increasing inlet coolant flow rate enhances heat dissipation efficiency but increases pressure drop. Reducing inlet coolant temperature is a useful approach to enhance the cooling capacity of the liquid cooling plates, but its effect on the temperature uniformity improvement is insignificant. We further study pack-level liquid cooling systems with four different structures for a 10 kWh battery pack. The system design with interspersed cooling plates shows the best performance, which can reduce the maximum temperature of the battery pack to 36.3 °C and effectively dissipate around 62.2% of the heat produced by the batteries under 2 C discharge. Moreover, the temperature difference is decreased by 10.5% with appropriately arranging coolant flow directions. In addition, increasing the coolant flow rate and lowering the inlet coolant temperature can greatly enhance heat dissipation capacity, while the latter parameter shows little influence on the pack temperature difference.

To minimize energy consumption, we develop a passive thermal management system by taking advantage of water desorption process. Specifically, metal-organic framework [MIL-101(Cr)] particles with high water adsorption capability are uniformly coated onto a copper foam. The MIL-101(Cr) particles can absorb water from the atmosphere and release vapor to dissipate heat when the battery temperature increases, while the copper foam acts as a thermal conductive network to transfer the heat among the particles. Compared with natural cooling, air cooling and solid-liquid phase change material cooling, the proposed passive cooling method reduces the battery temperature by 7.5, 2.6, and 2.1 °C, respectively, at 3 C discharge. Additionally, the battery temperature is confined below 37.6 °C in the dynamic discharge-charge cycling test. For passive cooling of pouch lithium-ion batteries, we design and synthesize a boron nitride/agarose composite hydrogel film with high water content and improved thermal conductivity. It is demonstrated the composite hydrogel-based system can reduce the maximum temperature of the battery under 3.0 C discharge by 6.7 °C when compared to natural cooling. Furthermore, the superior performance of the proposed system is retained in long-term discharge-charge cycling test that the peak temperature and temperature difference are constrained below 41.5 and 2.9 °C, respectively.

To combine the advantages of active and passive cooling, we develop a hybrid thermal management system using composite phase change materials combined with forced-air convection for a 22.5 Ah cylindrical battery module. This unique combination enables the system to achieve good temperature uniformity and adjustable heat dissipation capacity. Under low power operation, the heat generation of lithium-ion batteries is small so that the passive mode of the system can well control the thermal performance of the battery module. At high discharge rates, forced-air convection helps to dissipate the heat stored in the phase change materials to maintain a good temperature control performance. Compared to the pure passive cooling, the hybrid system can lower the battery module temperature by 13.6% in continuous discharge-charge cycling test, showing great promise for the effective thermal management of lithium-ion battery modules.

Date of Award2022
Original languageEnglish
Awarding Institution
  • The Hong Kong University of Science and Technology
SupervisorTianshou ZHAO (Supervisor)

Cite this

'